Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Power Plant Engineering Interview Questions
Questions Answers Views Company eMail

What are the motors used in a thermal power plant? (With type and ht/lt) What voltage levels are used in a thermal power plant?

OPG,

2 15980

what is the meaning of SST300 V56A in SIEMENS turbine

Siemens,

4368

thermal power plants in steam using inlet of turbine.inlet of turbine pressure and flow is same as boiler feedpump why not use direct to turbine?

IBPIL, JSW,

6 13703

What will happen if id fan on boiler not functioning?.Can the Boiler run without id fan? What is the effect?

4 16032

dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job

dbpl,

2546

what is scanner air fan & how dose it work & is there any interlock in power plant

APGenco,

3 36713

During shutdown of Steam Turbine,How do we cross the critical speed?

OPG, Power,

7 19000

If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakage. Then it's motor current get affected or not??

1 3974

I want to build 100 megawatt hydel dam. What does mean, 100 MW per hour? then how many electric bulb of 100 Watts the dam would lit?

1 6883

What is df/dt protection?, How to calculate setting range of 30 MW steam generator???

DS Sugars, MEMF,

1 11864

what is the relation between the grid voltage and generator voltage how to link up generator with grid

NDFL,

3 8386

Need of oxygen dosing in super critical powerplants?

5 11821

63.5 ohm NGR is connected with our gas engine genrator running at 500 rpm, 50 hz and synched with WAPDA at 6.3 KV bus voltages, 2500A and 25KA(1 sec). can some one give me proper calculations how it comes 63.5ohm?????

UET,

2 5351

some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

UMT,

2427

what is the real reason than natural draught cooling towers are always in hyperbolic shape

2 8872


Post New Power Plant Engineering Questions

Un-Answered Questions { Power Plant Engineering }

How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

2291


How do you consider that you can improve and what assistance do you need to achieve this

1760


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1005


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2440


explain how the third harmonic content of the magnetising current affects transformer design

3279


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1702


what is restricted earth fault explain in details

2051


why do you consider yourself a suitable candidate for this position

7452


How We Calibrate the vaccum transmitter?

1978


What is difference between secondary Air & Tertiary Air and Their use.?

2009


what is the difference between compensated & normal drum level in boiler drum?

1811


what is the meaning of SST300 V56A in SIEMENS turbine

4368


Why superheated are started before I'd and rd fan?

2186


operation

1903


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

3412