What are the motors used in a thermal power plant? (With type and ht/lt) What voltage levels are used in a thermal power plant?
OPG,
2 15980thermal power plants in steam using inlet of turbine.inlet of turbine pressure and flow is same as boiler feedpump why not use direct to turbine?
6 13703What will happen if id fan on boiler not functioning?.Can the Boiler run without id fan? What is the effect?
4 16032dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
dbpl,
2546If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakage. Then it's motor current get affected or not??
1 3974I want to build 100 megawatt hydel dam. What does mean, 100 MW per hour? then how many electric bulb of 100 Watts the dam would lit?
1 6883what is the relation between the grid voltage and generator voltage how to link up generator with grid
NDFL,
3 838663.5 ohm NGR is connected with our gas engine genrator running at 500 rpm, 50 hz and synched with WAPDA at 6.3 KV bus voltages, 2500A and 25KA(1 sec). can some one give me proper calculations how it comes 63.5ohm?????
UET,
2 5351some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
UMT,
2427Post New Power Plant Engineering Questions
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
How do you consider that you can improve and what assistance do you need to achieve this
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
explain how the third harmonic content of the magnetising current affects transformer design
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
what is restricted earth fault explain in details
why do you consider yourself a suitable candidate for this position
How We Calibrate the vaccum transmitter?
What is difference between secondary Air & Tertiary Air and Their use.?
what is the difference between compensated & normal drum level in boiler drum?
what is the meaning of SST300 V56A in SIEMENS turbine
Why superheated are started before I'd and rd fan?
operation
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.