Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

if i want to make a zero trim for mass flow meter the pipe line should be empty or i need to make it full? i really need the answer pls help me

2 5519

How we can do the linearity test for Bently Naveda Vibration Probe?

Sabic,

1 18364

why level transmitter input is given 4to20ma

Sabic,

2 6780

why most of the DP transmitters using maximum range as 0-2500mmwc?why not 1000 2000 3000 4000mmwc

SPIC, TNPL,

2 8455

How we will check whether the proximity, which we have is either NPN or PNP, if no data sheet or manual or any details is available to us ???

1 6806

if change the pid in D value so what action.

Siemens,

2 8493

What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?

KNPC,

2174

Transducer Input 0 to 230 v ac Output-0 to 10vdc Receiver Input 0 to 10 vdc and Output 4 to 20 ma How?

1 3775

in DCS or PLC we can not put all ai or di,there is calculation through which we can accomodate certain no of digital and analog signal.I need to know that calculation

1 4691

How to control flow variations in magnetic flow maters..... When i will provide proper earthing?

ABB, L&T,

2372

how to calibrate displacer type level transmitter by dry weight method please mention formula for weight calculation

1 13593

if a dp transmitter has range 100 in H2O and flow is 20mmcf and if the flow is changed to 25 mmcf then what is the formula to determine new range of transmitter

TATA,

1 5766

What is the difference between uv and ir scanners? and what is the workig principle of both

2428

applications of plc in printing and packaging?

2271

what is protonics how it is differ from electronics

1 6717


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

How to measure the dust in chimney(spm)?

4148


How do you identify an orifice in the pipeline?

1312


Please can anybody help for control valve sizing step by step procedure?

2197


Which type of pressure can be measured by primary elements?

1091


Draw a great bridge circuit.

2059


May I have a brief note above the voltage barriers? Whats is the purpose? Please mail me if you've operational details, mail id: rajkumar.diice@gmail.com

2185


how to relay switch sense the fault?

2667


Give Detail information about plc,dcs,and scada system?

1784


Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.

2070


can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

2077


What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

1104


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

2221


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

2114


If fire would be inside the plant which fire detector is to detected the fire.

1662


In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.

2022