y v r connecting 250 ohms resistor in series when u cummunicate with BT in bench calibration?
5 8454I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )
4 9482my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
2263i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below
1 4786WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."
6 25794If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2096If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2 12960Post New Instrumentation Questions
why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?
draw shematic diagram of c/v positioner(smart type)?
Draw bode plot of any transfer function. Why is plotting bode necessary?
How to calibrate Toxic gas detector?
What is the purpose of the analyzer in petrochemical plant?
Why upper weighing limit of electronics balance is 90% of the total weighing capacity?
what effects a surging can produce in the compressor
what is the protection system in solar turbine compressor
Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?
why fuse block is not used for AI signal?
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
How to calculate P,I&D value in PID controller ?
Specific gravity.
my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.