Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

ABB Interview Questions
Questions Answers Views Company eMail

where rlc series ckt used?

2158

Why transformer ratings in KVA not in KW?

6 10268

what is the difference between arc and spark

2 7566

What is the differentional relay...what is the work of this in power Tx. how it is works..

1880

what is the safety of ACB & VCB and how can this work and how can the service the ACB & VCB parts name with picture

21 99947

what is ten delta ?

2 5817

how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?

2162

what mean by analog ,digital,numerical meters and relays? say the example?

2235

you are on site,the plant trips,you are approached by operations,what do you do?

2202

Hello friends., my question is related to testing of current transformer... A Ct having knee point voltage of 750 volts., and I have two step up transformer's of rating 230 v to 440 volts., can I obtain the value of 750 volts by using the two transformer's.... If yes then how could I connect the transformer's to obtain knee point voltage?? thank you in advance

1 4636

please anyone suggest me some good intools training institutes with their place and contact nos.

1 4045

I have 90KW Motor 60 Hz,380V Pf 0,88. after testing the Motor without Load is the no load Current 36 A,but wenn i put load after 2 hours the current increase more than 156 A. Can anybode tell me waht is the Problem?

4 7171

Hello friends, Can anyone explain the concept of zones in Bus bar protection and how can we differentiate the main zone and check zone in Bus bar protection

1 8666

Difference between earthing & grounding.?

3 6198

what is the function of a Master trip relay? why is it used ?

5 80980

Post New ABB Interview Questions


ABB Interview Questions


Un-Answered Questions

types of survey and levelling instrument ?

1805


What are the advantages and disadvantages of using flex? And why flex wins over other technologies?

5


What does the minimumprefixlength property of the autocompleteextender control do? : asp.net ajax

937


Does ‘default value’ do anything if the object is created through apex?

480


What is an application group and why would I want to use it ?

806


why IT?

1947


Does office 365 include ms access?

810


What is 0xc0000005?

703


What is extended star schema?

929


Which platforms does Silverlight support?

5


What is web service w3school?

620


Why we use xpath instead of css?

666


how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?

1856


How can I find out someone's age?

514


Explain the secondary structure of proteins?