What are the tests required to check the Quality of steel?
Answers were Sorted based on User's Feedback
Answer / samiran bhattacharya
The question is not specific about its requirement. There
are wide varieties of steel available and used in Civil
Engineering Construction Projects. But in general for steel
reinfocement bars that are widely used in RCC works
physical properties such as Tensile Strength, Yield
Strength, Elongation, Bend test etc. and Chemical
Properties like Carbon, Manganese, Sulphur ,Phosphorous
content etc. can be checked and compared with the relevant
specification.
| Is This Answer Correct ? | 50 Yes | 6 No |
Answer / er. munesh natrrajan[m.d. of d
Tensile strength,
Yield strength,
Weight,
Elongation.
& also A simple test called bend test conducted on site can
assess the quality of steel.
When you bend the steel rod to make an angle of 90 to 135
degrees and then bend it back straight, there should not be
a cracks on it. If the original shape is retained/gained
once it is straightened, you can assure that it is of good
quality steel.
| Is This Answer Correct ? | 46 Yes | 2 No |
Answer / dipesh
tensile test, bend,rebendtest,its unit weight/kg,diameter.
| Is This Answer Correct ? | 17 Yes | 3 No |
Answer / ramesh
To find out the quality of steel in construction purpose
1.check Tensile and Shear test
2.check Bending moment
3.check the length as 40ft or 12.19m
| Is This Answer Correct ? | 15 Yes | 3 No |
Answer / shaik mahammad sharif
1.Type of Material
2.Use of Material
3.Weight for Foot(rebar only)
4.Tensile Strength
5.Percentage of Elongation
6.Ultimate Tensile Strength
| Is This Answer Correct ? | 3 Yes | 1 No |
Answer / harish
the quality of steel chek for tensil strenght & elongation
bend test & also weight the bars
| Is This Answer Correct ? | 6 Yes | 6 No |
Can we weld hot rolled steel ASTM A615 ?
how to calculate steel quantity of column from steel design
ground floor columns and beams are reinforced by 4 Num's 16MM @ Corners AND 2 Num's 10MM @ centre.... And the nxt top floor columns and beams were lapped by 8 num's 12MM dia bars..... IS THIS CORRECT ????
what is rebaring?
what is the concrete grade for 1034.13N/mmsq
what is the initial setting time & maximum duration concrete get hardening for ordinary portland cement?
Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No. Loading Axial force Moment Shear 1 DL+LL 1950 600 20 2 Seismic load 250 4800 700
how much the volume of one packet cement ?
The definition of national highway
diffrence between mjb & mnb
Characteristics of a model project are ––
according to the painting co efficient, we should take the one side of doors (or) windows or both sides?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)