1)Why electric shock is feel ?? n in a Electric Train why
we didnt feel that ?
2)What is the reason for transformer Noise ??
3)What is relation b/w Transmission Lines & Communication
Lines ?
4)Which material is used for making Transformer oil & How u
measure its dielectric strength & Name the test ?
Answers were Sorted based on User's Feedback
Answer / sbb
1) This is a simple thing, as we know that current is define
as flow of electrons and at a same time flow of electrons
from higher potential to lower potential is called potential
difference.so whatever the shock we feel is nothing but
power i.e., P=V*I.that is electrons will flow in body
nothing but current and from body to ground is voltage.
In Electric Traction power is taken in the locomotive
through ht bushings and it is proper insulated.
2) The reason y noise will occur in transformer is due to
the electromagnetic induction in primary and secondary,as
well as due to leakage flux in the core.
3) Transmission lines:We use material made of Aluminum
conductor in Tr.lines and it is bare conductor.there may be
a corona effect in tr.lines.
Communication lines: We use material made of copper and a
same time it is a screened cable,for which there is no
interference with power line or and other form.
4) Material used for Transformer Oil is Product of Petroleum
products and the scientific name of the T/F oil is
Askerals.Dielectric strength of the T/F Oil test or it is
measure by "Break-Down Voltage" test.
| Is This Answer Correct ? | 1 Yes | 3 No |
ya hi rajkumar i agree wit u its due to vibration but i had
not conformed tat the answer was correct
| Is This Answer Correct ? | 1 Yes | 4 No |
Answer / kaarthikrt&c09894209497
1.if v touch a live wire,using ur body it gets a ground so
u feel shock,in case of electric train every compartment
wheel is grounded(negative dc) so u cont get shock even if
fault occurs
2.i think its corona loss
3.trans lines used for carrying power,trans lines can also
be used as a communication line using PLCC power line
carrier communication
4.material who needs/IL335 is the indian standard oil for
tfmr oil.u can measure the dielectric strength by doing a
Break down voltage test(dielectric test for oil)
| Is This Answer Correct ? | 7 Yes | 11 No |
Answer / vasavi
1 electric shock ocuurs coz our body acts as a
path /conductor for current.
current lows frm faulty equipment - though us - and then to
ground
we dont get shocks in train i think bcoz in trains our
bodies are not grounded ,its moving
2 tf noise occurs due to a phenomenen
called "Electromagnetic striction"
4 T/f oil is made from crude petroleum (actually by product
during petroleum manufacturing process ) its purified n
used
Well i dont know the test name
| Is This Answer Correct ? | 11 Yes | 34 No |
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.
what is work of choke in tube light?
can any one provide me a connection wiring diagram for a DG set control panel along with BOM?
what is the difference between the following 2 situations ? 1)Line & Neutral=240V Line & Earth=230V Neutral & Earth=10V 2)Line & Neutral=230V Line & Earth=240V Neutral & Earth=10V
what is meant by neutral compensation factor and where it is used
what is diff btw electric,magnetic & eletromagnetic field
What is the meaning of transformer 16 / 20 mva.
What is EHT tariff or Power factor Tariff ????
If oil and air can withstand a high MeV when used as an insulator in a transformer, what are the values of how high for each material?
what are the effects of variations in frequency when you are connected to national grid??
what is power factor
What is non-minimum phase transfer function?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)