Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why reverse power relay is used?

Answers were Sorted based on User's Feedback



Why reverse power relay is used?..

Answer / linda

Whenever EB cut off, Automatically generator will on .
after an hour if EB resumes back, Generator should off , in
that situation there is a possibility to flow the power in
reverse condition, if it so, then generator bacomes motor.
to avoid this reverse power relay is used.

Is This Answer Correct ?    6 Yes 14 No

Why reverse power relay is used?..

Answer / aladeen

generator out put volteage in control room but will not
out put from costumer(the remark reverse power)

Is This Answer Correct ?    1 Yes 28 No

Post New Answer

More Electrical Engineering Interview Questions

How to Design green buildings services? What is the advantage to design green building?

0 Answers  


In a company has been installed an analog amperemeter, this company was suplied by generator X, there is no problem in the ampere meter, rigth now this company's supplied by generator Y then the pointer in amperemeter vibrating. What happened? Why? Thank's

2 Answers  


what is the surge arrestor?how it operates?what is the range for it?

4 Answers  


what will happen if transformer given dc input

5 Answers  


What are the advantages of individual drives?

1 Answers   A1 Electricals, Suzlon,


How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks

1 Answers   Siemens,


Why frequency fix in 50 Hz?

6 Answers  


What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.

0 Answers   MSETCL Maharashtra State Electricity Transmission Co Ltd,


What is the difference between Droop vs Isoch Control?

0 Answers  


What is the power factor of a transformer at no load?

0 Answers  


why the value of impedence is taken as %impedence in fault currrent calculation

1 Answers  


Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

0 Answers   Shree Mayur Engineering,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)