what is the function of nozzle?
what happend when the fluid flow through a taper pipe
i.e. what about inlet and outlet velocity, pressure,
Answers were Sorted based on User's Feedback
Answer / anu
nozzel is a device which convert (high pressure and low
velocity fluid) at inlet into (high velocity fluid and low
pressure) at exit
| Is This Answer Correct ? | 184 Yes | 21 No |
Answer / gaurav sharma
nozzle is the device which is used for converting fluids
pressure energy into kinetic energy. if a fluid is passed
through a tapered pipe its velocity is higher at the outlet
as compared to inlet
| Is This Answer Correct ? | 124 Yes | 15 No |
Answer / shrish
Nozzle work on two principal :
1. Countinuty Equation
2. Bernoulli's Principal
So if Area of Crossection decrease then velocity will
increase i.e. velocity head increases that will affect on
pressure head.
Means velocity increases & pressure decreases at outlet.
| Is This Answer Correct ? | 65 Yes | 12 No |
Answer / karthick
the function of the nozzle is to convert heat energy into
kinetic energy.the inlet velocity will bw minimum but
pressure will be high whereas the exit velocity will be
maximum and pressure will be minimum.the nozzle consists of
three sections convergent ,divergent and throat.the fluid
attains velocity less than sonic in convergent and sonic
velocity (i.e., mach no=1) in throat and supersonic
velocity in divergent section.
| Is This Answer Correct ? | 33 Yes | 11 No |
Answer / amit bhopale
Nozzle is a taper tube which drop pressure at inlet and
increase velocity at outlet
| Is This Answer Correct ? | 10 Yes | 1 No |
Answer / mani kandan
Nozzle which is used convert a pressure energy to kinetic energy
| Is This Answer Correct ? | 10 Yes | 3 No |
Answer / sandeep kumar
nozzle is used where we have high pressure and low velocity or k.e.but we needs low pressure and high velocity.
nozzle are generally of two kinds 1.CONVERGENT 2.DIVERGENT.
the nozzle whose inlet dia is greater and outlet dia is smaller is known as convergent while the nozzle who has low dia at inlet and large dia at outlet is known as divergent type nozzle.
WHEN WE PASS THE FLUID THROUGH A NOZZLE,ITS PRESSURE DECREASES AND VELOCITY INCREASES.
INLET VELOCITY <<<<< OUTLET VELOCITY
INLET PRESSURE >>>>> OUTLET PRESSURE
| Is This Answer Correct ? | 10 Yes | 6 No |
Answer / gatish mittal
the basic funtion of pressure nozzles is to convert the
pressure energy supplied by the high pressure pump into
kinetic energy in form of a thin film, the stabily of which
is determined by the properties of the liquid. such as
vescosity, surface tension, density and quality per unit of
time, and by the medium into which the liquid is sprayed.
the inlet pressure of pipe is more than outer pressure and
velocity is less than the outer velocity.
the velocity of nozzle is depends upon the ending point
diameter of nozzle, when a ending point of diameter of
nozzle is less than the velocity of fluid is more.
| Is This Answer Correct ? | 4 Yes | 4 No |
Answer / kundan kumar
It is a steady-flow energy transformation device which has varying Cross-section & it transform "high pressure energy { in form of heat energy } into high kinetic energy {high velocity }
| Is This Answer Correct ? | 0 Yes | 0 No |
Answer / ali
the importance of a venturi meter in the flow measurement system
| Is This Answer Correct ? | 3 Yes | 9 No |
What is the real meaning of quality
HELLO EVERYONE ..NOW IAM WORKING AS QUALITY CONTROL ENGINEER IN SAUDI ARABIA, I HAD 3 YEAR EXPERIANCE WITH REFINARY PLANT ,PETROCHAMICAL PLANT,ETC... NOW I PLAN TO DO APL 510 CERTIFICATION COURSE. BUT I DON T HAV IDEA FOR OFFERTINUTY FOR THIS.....ITZ GOOD OR BAD I DON T KNOW ? PLEASE ANYBOBY LIKE GIVE ANS ..ITZ HELP FOR MY LIFE ....
first law of thermodynamics deals with
What is the full form of wcb in astm?
how did you go into the mechanical engineering
If we measure the pressure of Air in duct with the help of Pitot tube attached to manometer (pitot tube) whose one end is in atmosphere and one end is in duct and manometer shows some head whether it is Static head or Dynamic Head or (Total head=Static head + dynamic Head). and if it is total head in which static head is zero then how static head is zero.
What type of pump is commonly used is feed water system in auxiliary boiler?
0 Answers ABC Inc, RRB, Siemens,
how to calculate the turbine efficiency?
how can you describe yourself
0 Answers Marriott, SEIL, Simplex,
What causes damage to impellers?
Double block and bleed is...
What is fuel ratio ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)