What is the import procurement cycle?
No Answer is Posted For this Question
Be the First to Post Answer
Define pcbs?
respected sir,i have been selected in the written examination(CHEMICAL) of IOCL Panipat held on 30 m1rch, So please tell me which type of questions asked in this interview frequently.Can u mail me some questions?
22 Answers HCL, HCPL, HPCL, IOCL,
what is isochronus and droop speed?
repected sir i have given gate exam today.......... if i ll get the better rank in that ....what is the next process .....shall i give another one test......or wat....i dint get properlly..... plz help me or mail me on Nish_gasti@yahoo.co.in
could any one plzz give me the placement tech papers taken by iocl,and bpcl in chemical stream..... my id is.... mishra.gaurang@gmail.com
What is a good estimate for the absolute roughness for epoxy lined carbon steel pipe?
Question 66 – The drag coefficient Cd = 0.05 and lift coefficient Cl = 0.4 for a levelled flow aircraft are measured. The velocity of the aircraft is v = 150 ft / s with its weight W = 2677.5 pound-force. (a) Find the value of the lift of the aircraft, L, when it is also its weight. (b) The drag of the aircraft, D = Cd M, L = Cl M. Find the value of D. (c) The power required is P = Dv. If 1 pound-force x (ft / s) = 1.356 W, find the value of P in the unit of Watt or W.
NATURAL GAS ENGINEERING - QUESTION 26.1 : (a) In natural gas pipe sizing, the length of the pipe from the gas source metre to the farthest appliances is 60 feet. The maximum capacities for typical metallic pipes of 60 feet in length are : 66 cubic feet per hour for pipe size of 0.5 inches; 138 cubic feet per hour for pipe size of 0.75 inches; 260 cubic feet per hour for pipe size of 1 inch. By using the longest run method : (i) Find the best pipe size needed for the capacity of 75 cubic feet per hour. (ii) Estimate the suitable range of capacities for the pipe size of 1 inch. (b) The maximum capacities for typical metallic pipes of 50 feet in length are : 73 cubic feet per hour for pipe size of 0.5 inches; 151 cubic feet per hour for pipe size of 0.75 inches; 285 cubic feet per hour for pipe size of 1 inch. By using the branch method find the best pipe size needed for the capacity of 75 cubic feet per hour when the length of the pipe from the gas source metre to the appliance is 52 feet.
What are the frequently asked technical questions in chemical engineering during PI?
Explain various protein purification techniques?
HOW WOULD YOU CALIBRATE A ROTAMETER
What are the apt definitions for apparent power, active power and reactive power? Explain about different types of lamps?