What are some guidelines for sizing a psv for a fire scenario on a vessel in a refinery service?
No Answer is Posted For this Question
Be the First to Post Answer
PLZ ANYONE SEND ME PLACEMENT PAPERS OF I.O.C.L MY ID---- gaurav.nitw.5609@gmailcom
At what temperature is glass fused to steel in the making of glass-lined equipment?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
What chemical is used to expand air bags in such a short amount of time?
Hi, I am in need of interview questions from Engineers india limited in chemical engineering.if any one has kindly post it to me soon.
How instrument air is continually supplied in process plant?
QUANTUM BIOLOGY - EXAMPLE 33.1 : In quantum biology, conditional entropy is given by H (S | O) = H (SO) - H (O). With reference to such equation, find another equation for H (SA).
UNIT OPERATION - EXAMPLE 9.2 : A distillation column separates 10000 kg / hr of a mixture containing equal mass of benzene and toluene. The product D recovered from the condenser at the top of the column contains 95 % benzene, and the bottom W from the column contains 96 % toluene. The vapor V entering the condenser from the top of the column is 8000 kg / hr. A portion of the product from the condenser is returned to the column as reflux R, and the rest is withdrawn as the final product D. Assume that V, R, and D are identical in composition since V is condensed completely. Find the ratio of the amount refluxed R to the product withdrawn D. Hint : Solve the simultaneous equations as follow in order to find the answer (R / D) : 10000 = D + W; 10000 (0.5) = D (0.95) + W (0.04); 8000 = R + D.
Please help to get IOCL/HPCL or other chemical engineering paper pls send kathir_skv@yahoo.com Regards, kathirvel
Explain what are the methods involved to test helium leak testing in a vacuum system?
Explain how does a tank-blanketing valve operate?
What is the working of vaccum distilation coloumn in a petroleum refinary?