How much carbon loading in nomalphase columns?

Answers were Sorted based on User's Feedback



How much carbon loading in nomalphase columns?..

Answer / ajinkya

it contain only silica, and in reverse phase c8 and c18

Is This Answer Correct ?    1 Yes 1 No

How much carbon loading in nomalphase columns?..

Answer / umesh chand

Normal phase column have no number of carbon ,its having silica gel particle coated with cellulose (3,5-di methylephenylcarbamate) and amylose (3,5-di methylephenylcarbamate)
like CHIRALPAK-OJ-H,CHIRALPAK -IA ,IB ,IC and etc.
'' polar stationary phase and nonpolar mobile phase'' use in normal phase chromatography
but carbon having hydrophobic nature, therefor we can't carbon loading in normalphase column.

Is This Answer Correct ?    1 Yes 1 No

How much carbon loading in nomalphase columns?..

Answer / deepak

8 carbon

Is This Answer Correct ?    1 Yes 4 No

How much carbon loading in nomalphase columns?..

Answer / priyanka

8 carbon

Is This Answer Correct ?    0 Yes 3 No

How much carbon loading in nomalphase columns?..

Answer / anand

Maximum 18

Is This Answer Correct ?    0 Yes 4 No

Post New Answer

More Analytical Chemistry Interview Questions

What is aggregate and fragments in SEC?

0 Answers  


What is use of LOD and LOQ in validtion and give range and in calculation why we use 3.3* LOD here why we use 3.3

2 Answers   Dr Reddys, IPCA, Reddy Labs,


what is the difference between c-8 and c-18 column

7 Answers  


why ph is between 0 to 14

6 Answers   Apotex, Reliance, Zydus Cadila,


what is custom fields in waters system?

1 Answers   Akorn India, Aurobindo,






what is difference between GC & GC-HS

11 Answers   SRF,


void volume is depending on column or not? if yes how will you depend?

1 Answers   Granules,


how you start RS method development when for new product?

0 Answers  


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

0 Answers  


HPLC Calibration was done in Reverse Phase, but not in normal phase why explain?

11 Answers   Cipla, Orchid,


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

0 Answers   JBCPL,


when we have polar type of sample and solvnt hen which type of stationry phase we have to use

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)