Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc test is replaced with hplc test. At the 4th year frequency the product is failed in hplc test .how can i assain the expiry or retest date and can i stop or continue the programme?

Answers were Sorted based on User's Feedback



stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc..

Answer / guest

The product is assigned 3 years expiry.

Is This Answer Correct ?    0 Yes 0 No

stability study is going on up to 3years for famotidine-USP but the pharmacopeia is revised and tlc..

Answer / ruchi

Please do not join ZEON lifescience paonta sahib as this company don't give offer letter and on the joining date they refused to get you in. So plz do not join this company for your better future.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Why methanol & acetonitrile is mostly used for hplc analysis?

2 Answers   DRL,


How to Perform a Recrystallization ?

4 Answers  


what are the primary standards of redox titrations?Name any two.

2 Answers   Laurus,


why in uv we take k value less than 1

2 Answers  


What is the difference between uplc and hplc

4 Answers   AAU Assam Agricultural University, Hetero,


why 0.02% solution toluene &noHexane using in uv calibration?

1 Answers   Graviti Pharmaceuticals, Orbit Pharma, Ranbaxy, Vimta Labs,


what is the maximum flow rate in prep hplc

1 Answers   Meril Life Science,


What impact analysis required for out of calibration and how to proceed

2 Answers   Aventis,


if you have given one product then how you determine the impurity in that?

0 Answers  


What is the difference between the working standard and reference standard?

1 Answers  


what is the difference between potentiometric titration and karl fischer titration?

0 Answers  


If i performing one analysis on C8column then the same analysis done on C18 column then what will happen about Rt;Resulution;Peak shape Explain ?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)