Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


is it possible to say motor horsepower number without seeing
name plate(when name plate damaged)

Answers were Sorted based on User's Feedback



is it possible to say motor horsepower number without seeing name plate(when name plate damaged)..

Answer / murugavel

can you find in motor full load current and multiplication in voltage you will find out motor KW after 1KW= 0.742 hp

Is This Answer Correct ?    1 Yes 0 No

is it possible to say motor horsepower number without seeing name plate(when name plate damaged)..

Answer / simon

Yes
1HP=735.5Wt
use 50-60Amp (AMMETER)
with 500v (voltmeter)
Hense P=V*I.....

Is This Answer Correct ?    0 Yes 0 No

is it possible to say motor horsepower number without seeing name plate(when name plate damaged)..

Answer / d k verma

By taking the frame size of the motor,by comparing the motor to the other available motor.

Is This Answer Correct ?    2 Yes 4 No

Post New Answer

More Electrical Engineering Interview Questions

Type of motor stater detail and working detail

0 Answers  


Actually why the transformers are rated in KVA.?

4 Answers   BSL, Engineering,


Then what do you call a transformer that is installed on the ground?"

1 Answers  


what is the contact resistance of vacume circuit breaker??

1 Answers  


Which is remain unchanged in transformer action?

6 Answers   NTPC,


how to calculate the settings for shaft ct protn in hydro generators

0 Answers  


I have lowered a submersible pump having 100 LPM discharge & 130 Mts. Head, 15 HP rating on borewell. After lowering 108 Meters, It is taking 39 amps & blowing the fuse. Can someone put light what is the cause behind it ?

1 Answers  


How to check the LM324 Ic

0 Answers  


why rating of motor in HP

2 Answers   MSL,


in transfomer which type of oil is use!

9 Answers   Essar,


how many types control panel of a 132/33 kv substation

0 Answers   Alstom,


In simply words(not explain any formula )what do you mean by power factor.?

5 Answers   DRDO,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)