Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the role of SO2,I2, Methanolic hydroxide and any
base in Karlficher titration

Answers were Sorted based on User's Feedback



What is the role of SO2,I2, Methanolic hydroxide and any base in Karlficher titration..

Answer / himal patel

meoH use as a media,when S02+water+MeOH,and base react it
give intermediatealkyl sulphite salt which is oxydised by I2
and give alkyl sulphate in this oxydation reaction water
consume.and water is consume is (1:1) of I2,when all water
consume Excess amount ofI2 detect voltemetrycally by refrence
electrode<and water amount is calculated by consumption of KF
reagent

Is This Answer Correct ?    14 Yes 0 No

What is the role of SO2,I2, Methanolic hydroxide and any base in Karlficher titration..

Answer / pharmainterview

I2 reacts with water.
CH3OH maintain the stoichiometry of rection
SO2 balancing the reaction.
BASE maitains the pH of reaction.

Regards
http://www.pharmainterviewquestions.blogspot.in/

Is This Answer Correct ?    5 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Colorimtry

0 Answers   Dr Reddys,


what is the definition of limit of stray light in UV calibration

1 Answers   FDC, Zydus Cadila,


Why pH range is maximum 14.0

6 Answers   UPL,


how to regulate noise in HPLC?

2 Answers   Alkem Labs, Vimta Labs,


difference between quality and quantity

3 Answers  


class of solvent regarding Residual solvent e.g. Acetone his class

1 Answers  


Why chromic acid wash is not recommended by USP for glassware cleaning?

1 Answers   Lupin,


what is mean by 40 in the dissolution basket mesh size?

0 Answers  


I got 88.0 % assay for a drug in HPLC analysis for same injection i got 40.0% related substances is it possible? what is the relation between results of assay and purity?

5 Answers  


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

0 Answers   Apex, BNM, Ranbaxy,


How to determine water content of thioanisole? which interfere by KF titration?

1 Answers  


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)