Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the role of SO2,I2, Methanolic hydroxide and any
base in Karlficher titration

Answers were Sorted based on User's Feedback



What is the role of SO2,I2, Methanolic hydroxide and any base in Karlficher titration..

Answer / himal patel

meoH use as a media,when S02+water+MeOH,and base react it
give intermediatealkyl sulphite salt which is oxydised by I2
and give alkyl sulphate in this oxydation reaction water
consume.and water is consume is (1:1) of I2,when all water
consume Excess amount ofI2 detect voltemetrycally by refrence
electrode<and water amount is calculated by consumption of KF
reagent

Is This Answer Correct ?    14 Yes 0 No

What is the role of SO2,I2, Methanolic hydroxide and any base in Karlficher titration..

Answer / pharmainterview

I2 reacts with water.
CH3OH maintain the stoichiometry of rection
SO2 balancing the reaction.
BASE maitains the pH of reaction.

Regards
http://www.pharmainterviewquestions.blogspot.in/

Is This Answer Correct ?    5 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is reverse phase chromarography&normal phase chromatography

4 Answers   Aurobindo,


why KF factor is between 4.5 to 7.5 mg/ml ? why ? why sometime pyridine is used in analysis like in raw material solvent like acetone etc?

11 Answers   Aurobindo, GVK, Sohan Healthcare,


Can we interpret accuracy from linearity in method validation?

1 Answers   Dr Reddys, Lupin,


why 0.02% solution toluene &noHexane using in uv calibration?

1 Answers   Graviti Pharmaceuticals, Orbit Pharma, Ranbaxy, Vimta Labs,


0.1 atom gram of the unknown element( X)reacts with 2.4 gram of O2 to produce the oxid product . can you tell us, what is the oxid formula ? a) XO b)X2O3 c)XO2 D) X2O4

1 Answers   Ajanta,


Why noise test is performed at 254 nm in calibration of HPLC system?

4 Answers  


How do we fix the sample concentaryion in hplc method development?

0 Answers  


what is diffrence between specificity and selecivity?

0 Answers  


Why dissolution test is not performed in all of the products

0 Answers   Biocon, SDD,


state the principle of gas chromatography?

5 Answers  


How do we fix the sample concentaryion in hplc method development. What is the basis?

0 Answers  


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)