Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why we are injecting low load standard conc. while analysing Related Substances by HPLC?

Answers were Sorted based on User's Feedback



Why we are injecting low load standard conc. while analysing Related Substances by HPLC?..

Answer / rajkumar

It is the concentration of the Unknown impurity which comes
from the reporting threshold. For any query see ICH Q3B(R2)

Is This Answer Correct ?    6 Yes 0 No

Why we are injecting low load standard conc. while analysing Related Substances by HPLC?..

Answer / ravi kumar tummala

yes, we r injecting std injection at low concentrtion,one reason is impurity specification level and another one is to calculate the imp's against std area.

Is This Answer Correct ?    0 Yes 0 No

Why we are injecting low load standard conc. while analysing Related Substances by HPLC?..

Answer / sri

It is at impurity specification limit

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

can some other acids like nitric acid or HCl can be used in the calibration of UV.Vis. spectrophotometer????

2 Answers   Cipla,


What is discriminating media? How can u justify/select that which media (pH etc...)is suitable for your dissolution study of your compound?

5 Answers   Natco, SUN,


Wt s the use of linearity in HPLC method validation

4 Answers  


Can you please give a suitable definition and an example for understanding the words purity and potency.

6 Answers   Cipla, Malladi Drugs and Pharmaceuticals, Reddy Labs,


hii, i'm had a sample of 1L that gone through extraction & evaporation. i used 0.5ml of methanol for reconstitution before injecting the sample to HPLC. i made a calibration curve using a standard solution but now i'm confused about how to display the concentration i got from the sample. for ex. i got 0.2ug/ml how i'm gonna explane this is for the 1L ? please help .. i'll really appreciate it thanks

1 Answers  


what is the analytical procedure for COD and BoD

1 Answers   Dai-Ichi,


who is the father of HPLC?

6 Answers   Cipla, IPCA,


what is assay in hplc

3 Answers  


What is the difference between high pressure gradient and low pressure gradient in hplc?

1 Answers   Cipla,


Why pH range is maximum 14.0

6 Answers   UPL,


what is the difference between potentiometric assay and hplc assay

2 Answers   Parabolic,


in OSD forms require to use gas chromatography?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)