Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


in calibration of disintegration test apparatus why cycle
limit is 28-32?

Answers were Sorted based on User's Feedback



in calibration of disintegration test apparatus why cycle limit is 28-32?..

Answer / raja.s

Usp limit

Is This Answer Correct ?    3 Yes 0 No

in calibration of disintegration test apparatus why cycle limit is 28-32?..

Answer / nagesh

As per IP 28 to 32
As per USP 29 to 32

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

in hplc calibration injector linearity pass,it means inj and det is good. why to perform detector linearity is it required, if it is required,what is difference between injector and detector linearity in hplc calibration

4 Answers   Dr Reddys, Hetero,


Chromatographic Purity is a Qualitative analysis

2 Answers   Shasun Chemicals,


Why using Holmium oxide in UV calibration

8 Answers   Dr Reddys, Matrix, Nakoda Chemicals, Orchid,


How you will select column for HPLC development depends on nature of compound and how it will work explain in brief?

3 Answers  


why we use sodium salicylate in uv light calibration at TLC chamber

1 Answers   Aurobindo, Lee Pharma,


Why we are injecting low load standard conc. while analysing Related Substances by HPLC?

3 Answers  


what is the d/f b/w normality and molarity and molality..?

1 Answers  


why results are variation in same samples analysis in gc and hplc ?

2 Answers  


1)why use benzophenon,uracil in hplc calibration. 2)why use sucrose in polarimeter calibration. 3)what is S/N ratio, noise and drift in hplc 4)how we can find lod and loq in method validation

1 Answers  


what is reverse phase chromarography&normal phase chromatography

4 Answers   Aurobindo,


key components in hplc?

3 Answers   Laurus,


why water factor is near about 5.0 in kf titration?

3 Answers   Claris Lifesciences, Indchemie Health Specialities,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)