Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Which buffer is used for LC/MS mobile phase & at What Conc.

Answers were Sorted based on User's Feedback



Which buffer is used for LC/MS mobile phase & at What Conc...

Answer / haresh kidecha

generally volatile buffer used in LC/MS mobile phase.buffer
used in mobile phase is ammonium acetate ,ammonium formate
in concentration of 2-10mM for positive ions mode and 2-
50mM for negative ion mode.

Is This Answer Correct ?    14 Yes 1 No

Which buffer is used for LC/MS mobile phase & at What Conc...

Answer / chandra sekhar

In LCMS WE R USING ONLY VOLTILE BUFFER&CONC.OF BUFFER NOT
MORE THAN 0.05M&0.2%

Is This Answer Correct ?    10 Yes 1 No

Which buffer is used for LC/MS mobile phase & at What Conc...

Answer / balaji

In lc-ms volitile buffers only use conc upto 10mM maxium

Is This Answer Correct ?    3 Yes 2 No

Post New Answer

More Analytical Chemistry Interview Questions

why the sucrose used in calibration of polarimeter

5 Answers   Neuland,


WHAT IS THE DIFFERENT BETWEEN PURITY, POTENCY AND ASSAY

6 Answers   Glochem, Hetero,


Why we don't add Hcl, HNO3, H3PO4 in residue on ignition, why we add H2SO4

1 Answers  


how we can identify the impurity is coming below loq at transfering site?

0 Answers  


Why we are performing wavelength accuracy at lower and higher wavelengths in HPLC calibration

3 Answers  


In acid base titration, after complet consumption of HCl by NaOH, addition of next drop of NaOH will give pink colour with phenolpthalein indicator. Why this pink colour appear? Why not blue, black, green or anything elese?

3 Answers  


What is the reason for negative peak in HPLC while using UV detector.

2 Answers  


how to prepare working standard in our laboratory aganist reference standard ?

4 Answers   Merit Biolabs, Unichem,


what is the defination of accuracy & presicion?

8 Answers   Amneal Pharmaceuticals, GSK,


what are the primary standards of redox titrations?Name any two.

2 Answers   Laurus,


What are usp limits for total impurities,unknown impurity

1 Answers   Dr Reddys,


using gradient pressure in gas chromatography are not ?using gradient pressure why

0 Answers   Reliance,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)