What are all the type of vibration measurement measuring in
turbine, what is the output of vibration sensor.
Answers were Sorted based on User's Feedback
Answer / priyavats singh
there are many type of sensor used depend on company manufacturing ,but the working principle are, hall effect,eddy current and inductive transducer ,now a days eddy current is most commonly used
| Is This Answer Correct ? | 3 Yes | 0 No |
Answer / abu maryam
Vibration measuring philosophy may depend on position or speed measurement.
may be measured by sensor use npn transistor and eddy current produced from movable part affect it.
Some sensor is as bellows when the movable part touch it it give signal.
| Is This Answer Correct ? | 0 Yes | 0 No |
Answer / azam
there r diff companies which make vibration sensors and
their measurement and control panels (B&K germany)
output is in mV.
| Is This Answer Correct ? | 7 Yes | 9 No |
how to explain PID?
Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?
Explain the working of an electronic level troll.
how can we measure the level measurement with the help of pressure gauge?
HELLO FRIENDS PLZ EXPLAINE ME WHAT IS ORIFICE?AND HOW WE ARE USING IT IN INSTRUMENTATION
why we use double acting valve and where?
How to calibration coriolis flow meter?
what does mean by analog output trim and where this one used for?
I want to measure level under vaccum by using DP Tx and vaccum vary between -500 to -670 mmHg and process fluid is accetic anhydride if consider process fluid density 1 kg/cm2. how to calibrate Tx ? consider level is 0 to 100 Cm.
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2 Answers Gujarat Fluorochemicals Limited (GFL), Shell,
how can leve transmetter calibate in feild .and also put cv and flow plz .....
What is the right procedure for adjusting the gap voltage of bently nevada vibration sensor?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)