what is weight veriation in pharma industry ? plz explain me
Answer / manoj reddy
Uniformity of weight is an in process test parameter which ensures consistency of dosage units during compression.
Weigh individually 20 units selected at random and calculate the average weight.Not more than two of the individual weights deviates from the average weight by more than the percentage given in the pharmacopea.
130mg or less ± 10%
130mg to 324mg ± 7.5%
More than 324mg ± 5%
| Is This Answer Correct ? | 2 Yes | 0 No |
key components in gas chromotagraphy.
which are the guidelines for force degradation studies?
what does pH stand for?
What is the optimum period of storage of indicators?
1 Answers Orchid Chemicals and Pharmaceuticals,
What is the thickness of polystyrene film?
8 Answers Pharmaffiliates Analytics and Synthetics,
How to calculate LOD & LOQ in HPLC Validation Method
14 Answers Dr Reddys, GSK GlaxoSmithKline, Reddy Labs, Reliance, UIS,
Why KBR is used in IR for preparation of pellete, why it shows zero dipole moment
if tech transfer fails whay require to do?
What id the resolution factor
How to use RF and rrf in Rs calculation( either multiply or divide)?
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
give me method of calculating co relation of coefficient for HPLC,SOR & ANY OTHER