which brands HPLC COLUMN available in market
Answers were Sorted based on User's Feedback
Answer / eapen thomas
Phenomenex Luna,Chromadex,Supelcosil,Hypersil,Thermodex etc
| Is This Answer Correct ? | 8 Yes | 2 No |
Answer / satheesh kumar
In market,lot of columns are available few of them are
listed below-:
Columns,Bonded Phases Manufacturer
1)Symmetry C18,C8 Waters
2)X-Terra RP18,RP8 Waters
3)Sunfire columns Waters
4)X-Bridge Waters
5)Novapak C18,C8 Waters
6)YMC Pack C18,C8,CN,Silica YMC Japan
7)Phenomenex Gemini C18,LunaC18(2) Phenomenex
8)Zorbax SBC8,SBPhenyl,Eclipse Plus Agilent Technologies
9)Inertsil ODS3V,C8,Phenyl,C4 GL Science Corportn
10)Hypersil BDS C18 C8,Phenyl ThermoScientific
11)Devlosil ODS UG,HG,MG,C8 Nomura Chemical co
12)Kromasil C18,C8,Silica Akzo-Nobel
13)Prontosil C18,C8,Silica Bischoff
14)Nucleosil C18,C8,CN Sigma-Aldrich
15)Zodiac C18,C8,Silica,Phenyl Zodiac Life Sciences
| Is This Answer Correct ? | 6 Yes | 0 No |
Answer / d.raja sekhar raju
So many HPLC Columns are eavailable in market. that is YMC-
PACK ODS(C18),MOS-Hypersil(C8)&(C18),BDS-Hypersil (C8)&
(C18),Hypersil,Inertsil,Bond Pack & 'J' Sphere Columns are
available
| Is This Answer Correct ? | 8 Yes | 4 No |
Answer / rajit
Well, GL Sciences' Inertsil columns are really helping my
method development and validation operations. Inertsil
columns are well known in the Indian market for sure. Their
new InertSustain C18 column has a decent column
lifetime...Probably the next is Waters or Agilent's Zorbax
or Thermo's Hypersil BDS columns. For sure, there are too
many in the market.
| Is This Answer Correct ? | 5 Yes | 1 No |
Answer / amol
zorbax,kromasil,thermo,waters, water symmetry,& many more
| Is This Answer Correct ? | 5 Yes | 2 No |
Answer / said fernandez
The most widely used in the world would be GL Sciences'
Inertsil ODS-4 and Inertsil ODS-3 columns. Waters Xbridge,
Agilent Zorbax, Thermo Hypersil, YMC ODS-AQ, Phenomenex
Luna...etc
| Is This Answer Correct ? | 4 Yes | 1 No |
Answer / prashant
waters,agilent,thermo,lichroscart,zorbax,phenomenex,kromasil,supelco,YMC-pack
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / manikanta
Bischoff Prontosil are also there in indian market.They are cheap and best comapared to other brands
| Is This Answer Correct ? | 1 Yes | 1 No |
give me method of calculating co relation of coefficient for HPLC,SOR & ANY OTHER
Why the same type of columns showing different RT for a single product?
in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?
What should be the precision for HPLC during technology transfer?
if the flow rate is increases then any changes in retention time in hplc
what is role of pH in mobile phase
3 Answers Cipla, Dhanuka Laboratories,
What is post run in hplc?
difference between selectivity and specificity
2 Answers Troikaa Pharmaceuticals,
Why we have to take 42gm of sodium hydroxide instead of 40gm for preparation of 1M Sodium hydroxide as per Pharmacopia? Whether it means the formula for calculating molarity was wrong?