Answer / pankaj kumar
jump instruction
bit logic instruction
shift and rotate instruction
load and transfer instruction
word logic instruction
| Is This Answer Correct ? | 3 Yes | 0 No |
Answer / linilbabu.ck
Researcher & Developer
Please send more info regarding the simatic s700-300plc?
& developed Smallest CNC machines In single IC 89c51
My mail ID:lb.industries@yahoo.com
L.B.Industries
Perambra
calicut
Mob:9846956049
| Is This Answer Correct ? | 1 Yes | 1 No |
Answer / wayni
Please send more info regarding the simatic s700-300plc?
My mail ID:wayni@iway.na
| Is This Answer Correct ? | 0 Yes | 1 No |
Answer / mohi
sir, plz send me too the information, my mail ID: link2mohi@gmail.com
| Is This Answer Correct ? | 0 Yes | 2 No |
Answer / moath
send me your mail i will send you some thing veru useful
regarding S7 programing
| Is This Answer Correct ? | 4 Yes | 7 No |
How Honeywell FSC is functioning and what is its purpose? Can we bypasa it and only use DCS instead of that.
Can 2 transmitters be connected to Integral orifice meter taps? Does an integral orifice comes with 2 set of taps?
Sir i am studying M.sc,(Tech.)Electronics and Instrumentation in Andhra university.What is the offers for me?
Why we use the remote seal transmitters
what is loop folder?
1 Answers Bapco Bahrain Petroleum Company, Hyundai,
is here anybody who knows how to calibrate the pressure transmitter? ONLINE
How to force the bit in GE Mark V?
Someone please do mail me some instrumentation questions for Hindustan Petroleum test to avinalexander@gmail.com .Really would be gateful if someone could help me
3 Answers HPCL, Immersion, IOCL,
State some of balance principle’ advantages?
How can I zero check of wet leg type DP Tx ?
What is Difference between PLC and CNC ?
In RTU Panel we are having several Analogue & Digital Inputs /Outputs. We are recently facing some problems over Analog inputs , which are not updating properly (But Digital Input are updating normally) Can any one tell me from where the problem is creating , we have checked PLC CPU card, Analog Input card & we reconfigured ,But still the issue is there. Issue : 1. Sometimes Analog values are updating & sometimes not. 2. Analog values are not updating normally , showing some wrong Values 3. Total dead (0 value) Analog values are Level & flow measurement from the field instruments. (But in field the instruments are working normally & Displaying the values normally in local display unit) This problem we are facing in our Water Plant. If any one experienced this same problem or having any ideas related to our issue PLS send your valuable Answers/Replies...
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)