Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


WHY CAN WE NOT CHAGE SPEED OF SYNCHRONOUS
MOTOR...............................JUSTIFY

Answers were Sorted based on User's Feedback



WHY CAN WE NOT CHAGE SPEED OF SYNCHRONOUS MOTOR...............................JUSTIFY..

Answer / raja

It won't run in change in speed due to double excitation.
The motor runs in the synchronous speed due to magnetic
locking, if the speed decreases suddenly it get out from the
locking and goes to zero speed.

Is This Answer Correct ?    13 Yes 1 No

WHY CAN WE NOT CHAGE SPEED OF SYNCHRONOUS MOTOR...............................JUSTIFY..

Answer / mridul pandey

synchronous speed Ns=(120*frequency)/number of poles. Since
frequency and number of poles are constant and hence the
synchronous speed is constant and cannot be changed.

Is This Answer Correct ?    11 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

While DG is on Load? we can start the capacitor bank?

3 Answers   Inorbit,


what is the basic difference between capacitor and condenser ?

17 Answers   ABB, Essar,


What is PMG and AREP excitation system in generator

3 Answers  


why generation voltages are 6.6kv or 11kv and why not some one give that stander that generation voltages are 5kv or 12kv?

1 Answers   AES,


WHAT IS SYNCHRONISING?

8 Answers   L&T,


how to calculate cooling requirement of datacentre from electrical load?

0 Answers  


How to check the LM324 Ic

0 Answers  


What is the Levels of High Voltage, Medium Voltage & Low Voltage?

1 Answers  


How regulator control the fan speed?

4 Answers  


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.

0 Answers   PKR,


AC voltage only create magnetic flux in coils, but in Solenoid coil how 24V DC volt create flux and pick the plunger

5 Answers  


What is required of exietation to the alternater.

4 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)