What should be percentage of silt content in sand?
Answers were Sorted based on User's Feedback
Answer / vijay kumar jayswal
Not More than 8% by Volume Asper Cpwd Specification
Is This Answer Correct ? | 74 Yes | 10 No |
Answer / naresh kumar n
AS PER IS:383-1970 THE SILT CONTENT SHOULD BE MAX 3% FOR
UNCRUSHED SAND i.e, RIVER SAND AND MAX 15% FOR CRUSHED SAND
i.e, CRUSHED STONE SAND.
Is This Answer Correct ? | 53 Yes | 8 No |
Answer / md yunus khan
As per Is Codes By Weight Silt Limit Is 3%.
As Per CPWD Codes By Volume Silt Limit Is 8%.
Is This Answer Correct ? | 36 Yes | 3 No |
Answer / nagesh
I agree that percentage of siltcontent by weight should be
3% and by volume upto 8%, but can anybody tell why the
permissible silt content is 15% for crushed sand.
Is This Answer Correct ? | 21 Yes | 2 No |
Answer / g varun
AS PER IS:383-1970 for CONCRETE THE SILT CONTENT
1.SHOULD BE MAX 3% FOR UNCRUSHED SAND i.e, RIVER SAND
2.AND MAX 15% FOR CRUSHED SAND i.e, CRUSHED STONE SAND
As per is 2116 for mortor
1.SHOULD BE MAX 5% FOR UNCRUSHED SAND i.e, RIVER SAND
2.AND MAX 5% FOR CRUSHED SAND i.e, CRUSHED STONE SAND
Is This Answer Correct ? | 18 Yes | 6 No |
Answer / adesh kumar dohare
As per IS 383 Silt percentage in Content of sand minimum 3% and maximum 8%.
Is This Answer Correct ? | 8 Yes | 1 No |
Answer / g varun
for mortor purpose silt by weight is
5% for natural sand
5% for crushed sand
for concrete purpose silt by weight is
3% for natural sand
15% for crushed sand
Is This Answer Correct ? | 2 Yes | 1 No |
How to know proportions of cement, sand, aggregate in different types of grades like M5, M10, M20, M30?
what is mean by bulking of sand?
11 Answers CCCL, Kanakia Group,
how to find water-cement ratio perfectly proportions M20, M25, M30
WHAT IS THE DIFFERENCE BETWEEN FACTOR OF SAFETY AND PARTIAL SAFETY FACTOR?
can you give me the details of rate analysis of steel and concrete?
how sir calculate the slab steel and sir i want to know that how i calculate shutter works payments in cum and the rate is 120 per cum
What is the mixing ratio of M7.5,m10,M30,m35&m40?
15 Answers Reliance, Umiya Construction,
Can we provide lapping of R/f steel for plinth beam in support portion(At column)?
For submitting the project loan for bank Residential bldg,Suppose we take Provinding RCC mix 1:2:4 for footings No of footings,length ,Breadth,Height ,qty in cum, at last unit/Rate(Rs) ,i would like to know how do we get the unit/Rate
How many No of 4" Bricks Get consumed in 9" thick BB Masonary Wall of 1 cu.m.?
What is the weight of 10mm,20mm,40mm aggregate per cubic
what is the hanekom repairing material after concreting work