Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?
1582meter ratio is 100/5 CT ratio is 125/5, when the ratios changes i.e., CT ratio is 125/5 meter ratio is 100/5 what is the MF in boths conditions?
1 11597Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
1780Post New Electrical Engineering Questions
what is meant by class 1 E in electrical power supply?
what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?
Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???
R=*ΒΆ l/a
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
from which formula we select a capacitor rating?
11000volt DG set carnt kaise banvay
any idea abt REVERSE METERING concept.........?
what is meant by loss of field in a DC motor? how a universal motor works?
After completing iti in electrician, how can i get certificate of electrical supervisor? What ia requirements. For it?
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
I want to know how to calculate the size of electricity cable in building?
where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz
In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.