Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?
1530meter ratio is 100/5 CT ratio is 125/5, when the ratios changes i.e., CT ratio is 125/5 meter ratio is 100/5 what is the MF in boths conditions?
1 11523Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
1733Post New Electrical Engineering Questions
what is the stear deltaprinceple?
in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?
what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.
What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.
What descriptive information does the NEC require to be marked on all conductors?
How Can You Relate Power Engineering With Electrical Engineering?
What will happen if a dc source is given to a tubelight. Will it work or wont it work....
How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me
Why the moulded plug comes with domestic appliances instead of assembled plug like anchor, Vinay 5/15 A.
How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester.
how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me
Difference between on line capacitor and Station type capacitor
In parallel operation time both NGR’s close or not close if both close what will happen