In an electrical conductor, if current flows because of flow of electrons, then why not the conductor gets thinner day by day???
1 364610Hp, 3-phase, 415v, 50Hz induction motor. The above motor is to run on Star-Delta connection, so how do i make following hardware selection 1) MCB, 2) Contactor, 3) Wire Gage (Depending on P-P current or Line Current), 4) OLR, Please tell in detail how to do the above, so as to get the ans. of it even if the Hp rating changes.
1 6282Can we use a window type neutral CT instead of a bar type neutral CT. We have an issue with a neutral bar type CT of 800/1 ratio with a Circuit breaker NS800L shneider type, and we want to change it with a window type. Pls advise. Thanks
1 3352Lt trivector meter with ring type CT.Spec of meter are 3x240 v, -/5A. Ring ct spec. are 60/5A, line voltage- IL .66/3.0KV..what is the multiplying factor
1 3642Why we Do not connect the windings of the motor in delta? & what would happen if we do that? I mean the winding themselves not the three lines that are coming to the motor?
1 3354If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?
2287i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium...
1825we have a 2.5hp Starite electric motor water pump,the elec motor burned out,we need to replace starting capacitor(old capacitor specs erased),what microfarad rating capacitor do we need? 110-125V
1870Post New Electrical Engineering Questions
WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >
How can you sized or estimate the ligthning arrester current rating?
when we have to purchase the transformer by own i.e how much load will preferred HT connection?
What is the Resposiblity of Electrical Utility Engineer
what r the checklist while installing a 380 kva DG set
what is the difference between transformer,converter and transducer
is there any current and voltage drop on liquid resistance starter water/soda tank ?
What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.
What are the protections for safe running of electric generator?
what is meant by 3rd hormonics ?
why ht motors are star connected?
Define open loop control system.
the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?
Is neutral transformer can be called as control transformer?
Two electric lamps 40 W, 220 V each are connected in series across 220 V. What is the power consumed by the connection?