Hi friends I am a service engineer in electrical field i plan to shift design engineer in same field, so i request your suggestion for what software or course i want to learn ?
5 7236why some time Railway Fan not Rotate,But after a small rotation by human then it rotate normally? Why?
4 7142what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
2072Whot is the difference between MCB and MCCB.Whot is the selection critearea for MCCB and MCB for 63 Amp.
5 9387For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
1941length of 4 core cable 95mm from substation LV VFD panel to Motor at field approximately 150 meter. Motor stop and power has been isolated from LV MCC ( Substation )to disconnect Motor for services. After Motor completed service propose to reinstall and reconnect Motor Cable, found earth cable sparkling during touching at metal / motor body. Inspect by clamp meter found earth cable have current flow AC 1-2amps and all earth cable at MCC LV also have current flow as same value. why it is happen?
2 6040Post New Electrical Engineering Questions
what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration
How to calculate no of EARTH PIT? Describe the formula as per IS standard?
IF alternator SCR value will be high means what happen in alternator efficency at operating power factor of 0.8
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
Do you need any help with FEWA Electrical Supervisor exams?
Control wiring of a dol starter for forward and backward
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
Why we find the sensitivity for the CT's to check?
how does ELR works? explain
Which test will be more severe for VCB?
in my working site. momentary jerck in electrical supply ocurred frequently which cause of multiple losses in our electrical equipements. how can we protect our electrical machines and equipements in this situation.
What is dynamo?How it works and what is the function of dynamo in a DG.
how ups works ? various parts of ups and working principle
How to calculate mf when meter equipment and meter are connected