Hi friends I am a service engineer in electrical field i plan to shift design engineer in same field, so i request your suggestion for what software or course i want to learn ?
5 7356why some time Railway Fan not Rotate,But after a small rotation by human then it rotate normally? Why?
4 7281what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
2103Whot is the difference between MCB and MCCB.Whot is the selection critearea for MCCB and MCB for 63 Amp.
5 9527For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
1973length of 4 core cable 95mm from substation LV VFD panel to Motor at field approximately 150 meter. Motor stop and power has been isolated from LV MCC ( Substation )to disconnect Motor for services. After Motor completed service propose to reinstall and reconnect Motor Cable, found earth cable sparkling during touching at metal / motor body. Inspect by clamp meter found earth cable have current flow AC 1-2amps and all earth cable at MCC LV also have current flow as same value. why it is happen?
2 6106Post New Electrical Engineering Questions
How the over load setting for HT Motors calculated-provided in Numerical Relay
Define sensitivity?
can u please mail me the syllabus for GET exam for damodar valley corporation?
What are factors to be considered while we selecting the Core Balance Current Transformer for Earth fault protection
What should be the protection scheme for a 15kw, 3-phase motor working in a lathe machine.
v/f drive basic princeple
Mention the difference between Analogue and Digital circuit?
Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?
What are the relays in ACB and VCB
What is the difference between a 3 winding and 2 winding Potential Transformer
Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in
what is the role of energy meter in distribution system ?
how to calculate the tarriff for an industry whose kva demand is 10 mva
Why field rheostat is kept in minimum position while armature rheostat at maximum position?
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm