In case of a synchronous generator carbon brushes, some brushes expire before the others. Why is so? When all the brushes are installed at the same time, why don't thee expire at the same time?
1 2920Grounding. Dear all at one of my site we checked the amps at the earthing cable to the alternator it was found 125 to 130 A. at the neutal cable in same machine found 146A. in the same plant checked the earthing current on other alternator it was 52A, and neutral 116 A. we are facing problems with our controller and the card was damaged once. can that neutral/GND current be a reason? as there is common grounding for the Alternator,Brkr panel,Transformer?
2 3955Is there any Institution for giving M-tech in Electrical engineering for those who r in service? Give the details please.
2046what is the difference between interconnection and intraconnections in the circuit diagrams
NTPC,
8359how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?
3644Post New Electrical Engineering Questions
what is a power factor?
why r we using shell transformer for low voltage
pls someone send me sample question papers along with the key.thanks in advance
hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.
What is the type of earth fault protection used in battery? explain.
What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?
Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?
How would you relate your key competencies to this position?
In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?
if you are in a software company,then why do you want to come in a core company like sail, ntpc(where lots of trouble like tension but you have a good life in a it company) ?
For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?
WHAT IS VCB SAFETY
Why the earth to phase voltage is high 250 compare to other two phases
how to ctrl motor by use of ac or dc drive.plz explain evdintly
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?