Between AC generator(alternator) and DC generator which can be designed for high voltage and why?
1 4784Which is stiffer between salient pole rotor and cylindrical rotor synchronous machines? Justify your answer.
1 14525Which theory is used in the analysis of salient pole rotor synchronous machines? Who is credited for this developement? Could the same theory be used for cylindrical rotor synchronous machines?
1 6587Between rotating armature type and rotating field type arrangements which one is adopted for large rated alternators and DC generators.Why there is difference in the choice?
1 11621ho can we calculate the conductor insulation value according to their ratings like voltage,current etc.how insulation value related with voltage,current and power of amachine
2050Without seeing the nameplate descriptions of a rotating machine,Is it possible to say which one is a motor and which one is a generator? How would you certain this?
3 6513Post New Electrical Engineering Questions
relation between power station capacity and voltage level?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
How isolater function when installed inelectrical 440V wiring
What is knee point voltage of transformer?
what are the problems that generally occur in power flows??
What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.
how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.
what is counter poise conductors
How Can you do Maintenance of ACB of 2000Amperes
working function importance of mdc meter
Difference between HRG and NGR. Are they both the same thing
Give details on how you intend to handle a challenging position you are posted to manage unexpectedly as a company staff?
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
what is the write prosidure of stringing of 8meter pcc pole.
what is the relationship between current&voltage in practical purpose ?