Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
2405for measuring current and etc.,why we use value of 1.732 in three phase calculation. not in single phase.why
Bhel,
3 21126. Is there a simple method to measure the horsepower of a small motor (1-3 hp) for a non-technical person
2 4985i am also applied for the AAI jr executive (CIVIL) written test. pls forward me the syllabus & test pattern if any question papers, any one got reply for this quaries? if ANY ONE KNOW THE DATES OF WRITTEN EXAM PLZ TOLD ME. dreamyagrawal@yahoo.com
2 8025What is the specification of service line (ie from electrical post to cut out) used by electricity boards used in india.i mean which material,its size etc.. please give the answer at lalkishan.p@gmail.com
1971
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
which topics are come from quizs
What is boolean algebra?
Explain the concept of fly-by-wire technology and its advantages in modern aircraft design.
What do you measure in the banana and mountain diagram?
what are the Technical Specifications of D/240SC-T1
What does the catalystic converter on an automobile really do?
How can we calculate the per hour productivity of a hydraulic rock breaker,for excavator..
Define tons of refrigeration and cop.
What is the resonant peak?
what is high type road and low type roads
friends....i have been searching the model paper for HPCL officer trainee for chemical eng....tat apptitude section...if u people got any information regarding tat...please send me to my mail...my id is: maruthu.flower@gmail.com...pls send me wtever information u knew....thank u....
What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?
Please give the model or previous year question paper for the lecture post in government Engineering College (Electronics and Communication)
What conditions are required for transformer to operate at low frequencies ?