Telecom BSS related ques:
For cascaded 1800 BTS with master 900 BTS,if 900 master BTS
is down for its own equipment fault,cascaded slave 1800 BTS
gets down/stop carrying traffic without any fault as BCCH
and other controllong channels are in master 900 BTS.Is
there any technology/system to turn the slave 1800 BTS to a
single 1800 BTS autometcally when 900 master BTS is down
for its own equipment fault???It is possible to make the
slave 1800 BTS single live BTS manually.But I want to know
the autometic system/process.if there is any....if not
available, how can we generate the system??
Answers were Sorted based on User's Feedback
Answer / tilak
pls refer to hussain-09740091782.well experted.available at
any time
Is This Answer Correct ? | 23 Yes | 6 No |
Answer / ladiesman217
Might be using dual E1 in that case will be much more helpful.
Is This Answer Correct ? | 1 Yes | 0 No |
Answer / abhishek verma
Master bts 900 band and slave bts 1800 then master bts down so slave bts is also down because they have 900 band chgr(0