Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why Aluminium wires are used for High tension(HT) lines?
11 KVA/32KVA & aboue

Answers were Sorted based on User's Feedback



Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / a.ramaprasd

1. Economical. Aluminium is available in plenty. Current
flow is also less there fore conductor size is also less.

2. Considering economy we can use GI wire also , but it
will rust in due course , more rigid weighs more.

3. Cu 9 copper ) is better but it is expensive.Therefore
Alu minium is the best and wise choice.

Is This Answer Correct ?    31 Yes 5 No

Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / narendra mahadik

Due to low weight of aluminium as compare to copper and
easy to install. Sag is also minimum between the two polls.

Is This Answer Correct ?    16 Yes 2 No

Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / ha ha

There are two reasons
1. Economical.
2.Aluminium conductors do not produce electromagnetic
fields.Hence Electromagnetic Interference is less.Hence
they are used for HT lines.

Is This Answer Correct ?    20 Yes 9 No

Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / vilas

weight and cost & conductance are three factors are more
important for transmission lines, So aluminium is selected
to transmit power, as it is light weighted , cost also less
than copper, as weight is less the construction cost of
tower is less.

Is This Answer Correct ?    11 Yes 3 No

Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / parth

Since it is plenty in earth and less costly so way is their to be theft an has high resistivity so wire should be thin so that current can flow

Is This Answer Correct ?    1 Yes 0 No

Why Aluminium wires are used for High tension(HT) lines? 11 KVA/32KVA & aboue..

Answer / shubham batham

The conductivity of the silver is more than copper. and the conductivity of the copper is more than Aluminium, but As per availability of material in nature the Aluminium is used. other fact it is cheap and easily available. it is lighter so we choose Aluminium.

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

Is it true online ups having bypass mode if it is true then why we called ups because it is interrupting power when goes in bypass mode

0 Answers  


The height to which the liquid in a tank to be maintained for a certain constant velocity?

0 Answers  


tell me about vfd

8 Answers  


what are the safety measures of induction motor?

3 Answers  


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

0 Answers   Adani, Mahaveer,


is harmonic useful or it distort the alternating quantity?

2 Answers  


why capacitor bank always connected in delta,why not in star to a system?

15 Answers   NHPC, NTPC,


CAN A CD/CLOCK RADIO WITH 110V 60HZ WORK ON A 110V 50HZ FEED.

3 Answers  


What is stacking factor? What is its approximate value?

0 Answers  


Can an inverter be used as a converter? How?

0 Answers  


Give two basic sprrd control scheme of DC shunt motor.

2 Answers  


During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative

0 Answers   Core Solutions,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)