ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.33 : An engineering corporation that produces a type of healthy food has A number of shares of $B preferred stock and C number of shares of $H common stock outstanding. In a typical financial year, let the net income obtained = D. The amount retained by the corporation = E. (a) Calculate the amount of money distributed to the shareholders if : (i) D > E; (ii) D = E; (iii) D < E. (b) Let preferred dividend = F, common dividend = G, CH > G. Find the values of F and G, in term of A, B, D and / or E when : (i) (D - E) > AB; (ii) (D - E) < AB; (iii) (D - E) = AB.
ACCOUNTING AND FINANCIAL ENGINEERING - ANSWER 34.33 : (a) Amount of money distributed : (i) D - E, if D > E. (ii) D - E = 0, if D = E. (iii) Undetermined, when D < E. (b)(i) F = AB, G = D - E - AB where [ (D - E) - AB ] > 0. (ii) F = D - E, G = 0 where [ (D - E) - AB ] < 0. (iii) F = AB, G = 0 where (D - E) = AB. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
UNIT OPERATION - EXAMPLE 9.3 : In the distillation of binary systems by Mc Cabe Thiele method, the equation for the line of top section is given by y = [ R / (R + 1) ] x + XD / (R + 1). 2 points on the line are (0.99, 0.99) and (0, 0.36). Find the reflux ratio of R and XD.
What does extreme points in VLE curve represents??
4 Answers Reddy Labs, Reliance,
What is the maximum recommend pipe velocity for dry and wet gases?
y we do not differ b/w atomic mass and atomic wieght? from engrtauseef2008@gmail.com
How to size the cooling tower sump / basin for any given circulation rate? What is the guideline?
Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
can u tel me d question paper of gail?
Oil and fat containing food items are flushed with nitrogen. Why?
ENGINEERING ECONOMY - EXAMPLE 7.1 : In engineering economy, the future value of first year is FV = PV (1 + i). For second year it is FV = PV (1 + i) (1 + i). For third year it is FV = PV (1 + i) (1 + i)(1 + i) where FV = future value, PV = present value, i = interest rate per period, n = the number of compounding periods. By induction, what is the future value of $1000 for 5 years at the interest rate of 6 %?
Explain the largest application for surfactants?
Tell us about a time when you failed to meet a deadline. What were the repercussions?
4 Answers Bhavani Engineering Works, Caltex, Emirates, Holiday Inn, Regent, United States Seafoods,
Do you have recombinant protein expression experience? Explain?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)