Question 98 - The Planck-Einstein relation connects the particulate photon energy E with its associated wave frequency f to produce E = hf. Let h to be the Planck constant. The frequency f, wavelength L and speed of light c are related by E = hc / L. With p denoting the linear momentum of a particle, the de Broglie wavelength L of the particle is given by L = h / p. (a) Find the equation of E as a function of p and c. (b) If E has a unit of electron-volt and f has a unit of 1 / second, then what is the unit of h?
Answer 98 - (a) Let first equation : E = hc / L, second equation : L = h / p. Substitute the second equation into first equation will produce E = hc / L = hc / (h / p) = pc. (b) E = hf then h = E / f. Dimensional analysis of h will produce E / f of electron-volt / (1 / second) or electron-volt-second. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
what electricalcable size for 132kw motor 4pole
when power factor leading above 1 than defect moter and kwh.
Handpump harness water dont go back.Why?
speed control by the variation of field flux result in 1- constant power drive 2-variable torque drive
difference between gauges and comparator
What is smoke testing and sanity testing in software testing
why we use transformers?
group discussion important topics
i want MEIL placementt papers
In an existing power plant (phase I) with step up transformers (3nos) with Ynd1 vector group to the 400KV bus bar,an extension power plant (phase II) with transformers (4nos) with Ynd11 vector group >. what are the consequences of such configuration ,please note that % impedance are also differ i.e. 15% & 10.5% the reason was that auxiliary supply interface is at different voltage levels i.e 400v & 6.6KV in phase i and phase II respectively .please advise ! Thank you !
about metallurgy
0 Answers Bhushan Power Steel,
Question 95 - The following formula is used as a reference : (analyte signal) / (internal standard signal) = (f-factor) x (concentration of analyte) / (concentration of internal standard). A solution containing 3 mM of analyte and 4 mM of internal standard gave peak signals of 2 and 3 mamps respectively. Another similar solution containing 2 mM of analyte and 1 mM of internal standard gave peak signals of 1 and 4 mamps respectively. Find the average f-factor.
Software (196929)
Sciences (12521)
Engineering (38023)
Business Management (7372)
Accounting (11552)
Advertising Media (662)
Architecture Design (207)
Call Centre (2482)
Fashion Modelling (332)
Government (17383)
Law (806)
Tourism Hotel (377)
Everything Else (2322)
Military Police (160)
Skills Abilities (0)
Aptitude Questions (4305)
Placement Papers (705)
Certifications (3752)
Visa Interview Questions (2231)
Code Snippets (1098)
Entrance Exams (862)
ERRORS (16636)