Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why do we use KCl ,K2Cr207,Toulene & Halonium oxide for the caliberation of UV

Answers were Sorted based on User's Feedback



Why do we use KCl ,K2Cr207,Toulene & Halonium oxide for the caliberation of UV..

Answer / kumar

kcl will be used in Limit of stray light, toluene and hexane will be used in limit of resolution,K2Cr2o7 will be used in control of Absorbance and Holmium oxide will be used in control of wavelength

Is This Answer Correct ?    20 Yes 5 No

Why do we use KCl ,K2Cr207,Toulene & Halonium oxide for the caliberation of UV..

Answer / dipti shah

to check accuracy of wavelength scan

Is This Answer Correct ?    2 Yes 13 No

Post New Answer

More Analytical Chemistry Interview Questions

how can we determine RRF value in HPLC FOR CALCULATION OF IMPURITY ?

4 Answers   Macleods,


Why use in sodium salicylate in uv lamps calibration

1 Answers   Auctus Pharma, Reddy Labs,


what is method development parameter in HPLC method development

6 Answers   GVK,


what is the difference between loss on drying in ordinary oven technique and vacuum oven technique

4 Answers   Divis Laboratories, Ranbaxy,


what is the difference between capillary and glass column in GC

1 Answers  


In method developement or in any analysis if we use small length column for analysis what happen then ? why ?

3 Answers  


what is the working priniciple of ph, what are parts in ph meter

1 Answers  


Why do we use 500ppb sucrose and 500ppb 1,4 benzoquinone in TOC calibration?

6 Answers  


what is poarimeter, why it is used in pharma,and explain briefly about polarimeter?

3 Answers   GVK,


A new drug substance found fail to meet specification for an unknown Impurity during stability study(Specific change),how would further proceed?

2 Answers  


Wath is the differenc between two column HPLC wich have the samme support , lenth , pore size, etc.. But different name .for exemple : Spherisorb / lichrosorb

2 Answers   NDA,


if partition coefficient value was positive means, what it indicates ?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)