Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why we are using buffer solutionas as a mobile phase in hplc.

Answers were Sorted based on User's Feedback



why we are using buffer solutionas as a mobile phase in hplc...

Answer / t reddy

buffer is used to control the ph of the ionizable compounds

Is This Answer Correct ?    7 Yes 3 No

why we are using buffer solutionas as a mobile phase in hplc...

Answer / ramgepharma

suitable buffer will maintain the pH, what we adjusted

Is This Answer Correct ?    2 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

why IR graph or spectra comes down ? Any reason

4 Answers  


Why are use silicon oil mr?

0 Answers  


sop of a uv visible spectrophotometer double beam elico model

0 Answers   Sun Pharma,


How much area of methanol or other solvent are acceptable in blank (Diluent) of Gas chromatography.

2 Answers  


is there any material other than caffene to calibrate hplc detector

13 Answers   Biocon,


From peak purity spectrum, where or at which point peak purity angle & purity threshold is checked?

1 Answers   Cipla, MSN Pharma,


diference b/w packed &capilary columns

2 Answers  


What is peak purity and response factor in chromatographic analysis? Why we required to find out response factor?

2 Answers  


how to get accurate result for Residue on evaporation in purified water

0 Answers  


Dear sir, This is R.Kadambavadani working in a pharma industry. while doing RS analysis of ibuprofen API, unknown peak eluting some times in the 0.6 Min RT. Kindly send me what is the exact reason behind that. also am using ACN the mobile phase.

1 Answers  


what is the definition of limit of stray light in UV calibration

1 Answers   FDC, Zydus Cadila,


Why we are performing wavelength accuracy at lower and higher wavelengths in HPLC calibration

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)