Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


If i performing one analysis on C8column then the same analysis done on C18 column then what will happen about Rt;Resulution;Peak shape Explain ?



If i performing one analysis on C8column then the same analysis done on C18 column then what will ..

Answer / t reddy

consider ur performing combination drug.... if both the drugs hydrophilic means.

in c8 column the rt will be high compare to c18 and resolution between two peaks also will increase in c8.

i think peak shape won't affect based on this factor.

Reason - c8 is less hydrophobic than c18... because of less carbon.... c18 is more hydrophobic so the interaction between hydrophilic drug and high hydrophobic column(c18) is less, drug will elute quickly and RT will be less than c8 column and resolution also.

NOTE - this is just a possibility, u can still get the good Rt with c8 also by changing the various factors like mobile phase composition, flow rate, temperature etc

Is This Answer Correct ?    2 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

What is Standard deviation

2 Answers   Cipla,


Why we show ammonia vapours to tlc plate?to which compounds?

1 Answers  


what is Fourier Transform

3 Answers   Graviti Pharmaceuticals, GVK,


what is the results if we use ODScolumn instead of BDS column ,(ther parameter is same for column) in assay method ?

3 Answers  


Dear Sir, This is Thirunavukkarasu am working in Ordain Health Care AR&D, Am Having one problem While doing method development my question Metadoxine and Pyridoxine same chemical nature and structural activity i tried lot of methods but Analyte eluted same Retantion time i cant separate both peaks. solubility, pH both are same only only difference melting point metadoxine 210 C Pyridoxine 102 C please do the help needful for me

5 Answers   Ordain Solutions,


What is peak purity and response factor in chromatographic analysis? Why we required to find out response factor?

2 Answers  


What r the limitatoins of uv visible spectroscopy ? Why Water use in blank standard for uv visible spectroscopy ?

4 Answers   Cipla, Reddy Labs,


What is viod volume and peak purity in HPLC?

0 Answers  


why we wre doing linearity siudiec in hplc method validation

3 Answers   Cipla,


What is difference between silica used in TLC and HPLC column

4 Answers   Cipla, Meghmani Organics,


Calculate the water content in Di Sodium Tartrate (DST) based on molecular weight?

3 Answers  


what is the meaning of linearity,principle of co-relation coefficient?

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)