If i performing one analysis on C8column then the same analysis done on C18 column then what will happen about Rt;Resulution;Peak shape Explain ?
Answer Posted / t reddy
consider ur performing combination drug.... if both the drugs hydrophilic means.
in c8 column the rt will be high compare to c18 and resolution between two peaks also will increase in c8.
i think peak shape won't affect based on this factor.
Reason - c8 is less hydrophobic than c18... because of less carbon.... c18 is more hydrophobic so the interaction between hydrophilic drug and high hydrophobic column(c18) is less, drug will elute quickly and RT will be less than c8 column and resolution also.
NOTE - this is just a possibility, u can still get the good Rt with c8 also by changing the various factors like mobile phase composition, flow rate, temperature etc
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.
1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer
what is mean by peak intigrity?
CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?
how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,
in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?
[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?
what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me
Why potassium dichromate is used in calibration of uv?
For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?
How to set analytical specification for combination products?
Why irmoisture balance is used for corrugated box moisture testing
how to decide for one product require water content or LOD?
How to determine water content of bis tetrazole amine mono ammonium salt
what is mean by extactable and leachable study?