Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


how to correct peak when peak comes broader in shape?
How to do calibration of HPLC?

Answers were Sorted based on User's Feedback



how to correct peak when peak comes broader in shape? How to do calibration of HPLC? ..

Answer / satish

if peak is broad then use dilute solution of triethylamine to sharpen the peak

Is This Answer Correct ?    5 Yes 1 No

how to correct peak when peak comes broader in shape? How to do calibration of HPLC? ..

Answer / chanti1984

1. ENHANCE THE COLUMN OVEN TEMPARATURE, REDUCE THE SAMPLE
LOAD N COLUMN AND CHANGE THE DILUENT
2. URACIL/CAFFIENE SOLUTION ARE USING FOR CALIBRATION OF
HPLC WITH THEIR RESPECTIVE WAVE LENGTH

Is This Answer Correct ?    1 Yes 2 No

Post New Answer

More Analytical Chemistry Interview Questions

how to Calibrate FID IN GC

1 Answers  


How can we konw that the HPLC column is endcapped? Is it possible to identify visually without COA?

2 Answers   JBCPL,


In my analysis by HPLC,In sample main peak and placebo peak are eluting with shorter resolution ( almost look like doublet). how can i get max resolution ? Is changing gradient method is usefull?

3 Answers  


column washing procedure for normal phase and reverse phase?

1 Answers  


Why KBR is used in IR for preparation of pellete, why it shows zero dipole moment

7 Answers   GVK,


Why irmoisture balance is used for corrugated box moisture testing

0 Answers   Leiutis, Lupin,


What is the difference between chromatographic purity and related substances?

0 Answers  


what is the analytical procedure for COD and BoD

1 Answers   Dai-Ichi,


In method developement or in any analysis if we use small length column for analysis what happen then ? why ?

3 Answers  


in stress study if your api not soluble in hcl naoh h2o2 then what require to do?

0 Answers  


class of solvent regarding Residual solvent e.g. Acetone his class

1 Answers  


hi i am m.sc organic chem and complete analytical lab tech dipolma now job in qc many time ask question you in m.sc organic why job in qc please help me i can not give proper ans please tell me

3 Answers   Arch Pharmalabs, Natco,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)