Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to correct peak when peak comes broader in shape?
How to do calibration of HPLC?

Answer Posted / chanti1984

1. ENHANCE THE COLUMN OVEN TEMPARATURE, REDUCE THE SAMPLE
LOAD N COLUMN AND CHANGE THE DILUENT
2. URACIL/CAFFIENE SOLUTION ARE USING FOR CALIBRATION OF
HPLC WITH THEIR RESPECTIVE WAVE LENGTH

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

777


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1915


what is the difference between potentiometric titration and karl fischer titration?

3198


Related substance method equivalency on control sample or spiked sample?

779


Principle of single pan analytical balance

5145


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

991


How we can identify process related and degradation impurity in single method with short period?

829


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

2632


What is the requirement for brazil in the analytical method vslidation comparr to ich?

788


what is the procedure for cleaning of lenses of hatr accesory of ftir instrument?

2296


for which product require to do content uniformity? what is limit of cu?

821


What is the diffrence in japan mkt requirement in analytical method validation over US?

730


what is mean by 40 in the dissolution basket mesh size?

794


Identify problem faced when mass spectroscopy is used with HPLC system ?

1888


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

864