why does cooling chamber used in a gas turbine? why can't we
use exhaust hot air in the compressor?
Answers were Sorted based on User's Feedback
Answer / azhar iqbal
cooling chamber is used in the turbine to control it's
exhaust temperature and in this way to increase it's
efficiency by 2-3% almost.
Also it is used to protect the damaging of the turbine
blades as high temperature currents flow upon them after
combustion.
Is This Answer Correct ? | 7 Yes | 1 No |
Answer / osanandkumar
it used to dissipate or to maintain the specified
temperature of the turbine
Is This Answer Correct ? | 5 Yes | 2 No |
Answer / visu
in a compressor blade material uses for cooled air
only...not for hot air..
Is This Answer Correct ? | 1 Yes | 0 No |
Answer / eng.walid rezk
the compressor cannot work with the exhaust air
because if we do that the area under the curve of p-v
diagram will increase it is input work on an open system so
it equal -pdv as you must know so the area increases this
mean as well the work required increases and the over all
efficiency will decrease as well so in the two stage
compression cycle we had to make a water inter cooler to
reduce the work consumption
Is This Answer Correct ? | 1 Yes | 0 No |
How to calculate outer dia and width of the bearing
1>what is the material of ball bearing?
eligibity for TNPSC group 1 exam , age limit
What are SAE ratings?
if HP LP Bypass opened in running condition then what happen in 210 MW thermal plant
what thermo
what is difference between corrossion and erosion?
If any machinery or transmission needs periodic and regular lubrication what is the best method to give it?
2 Answers Focus Energy, Tech Mahindra,
What the significance of "HRC 5O" in Brinell's Hardness number?
Is it able to make FMEA for Pencil creation? If yes send the FMEA
How do you reset the circuit breaker?
What is the name given to ratio of actual cycle efficiency and ideal cycle efficiency?