Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why base line not starts from zero in gc?



why base line not starts from zero in gc?..

Answer / chennusrinivas

If baseline starts from zero it seems flame shutdown in
FID.Baseline value is depends on the Output value of the
flame, Output value clearly will shows in Agilent system.
Good Flame output value is "20"

Is This Answer Correct ?    10 Yes 2 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the difference between heavy metals and sulphated ash

2 Answers   Aurobindo,


what is difference of uv and pda

13 Answers   Akums, MSN, MSN Pharma, Shilpa Medicare,


is a bonded water molecule in an organic material can be easlisy and accuractly determined by KF rather than LOD

2 Answers  


In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you find and how proceed next step? ( Q is 80%)

3 Answers   Reddy Labs,


Why dissolution test apparatus calibration with salycilic acid tablets was stopped by FDA&USP from the year of 2009?

1 Answers   Aurobindo,


which solvent is highest poler acetonitrile dimethyl formamide methanole tetrahydrofurane buffer solution

8 Answers  


Polarized meter calibration, 1. Method name? 2. Which solution use? 3.why?

1 Answers  


if partition coefficient value was positive means, what it indicates ?

1 Answers  


In which situation we require to prepare the standard solution from sample in Related substance method?

0 Answers  


How to select Sample concentration in RS analysis?example.

1 Answers  


Why Deuterium lamp is used as UV light Source for UV.

4 Answers  


Why we are injecting low load standard conc. while analysing Related Substances by HPLC?

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)