what is the purpose of Buffer in any titration?Ex:In
determination of hardness of water we use ammonia
ammoniachloride buffer in titration with EDTA.Why?
Answers were Sorted based on User's Feedback
Answer / dinesh.m
use of the buffer is maintain the PH of the solution.........
Ex: Cyanodiole-HBr analysis in hplc v have use 3PH buffer solution as a mobile phase........
SUB:hard water means water having MgCl & CaCO3 r CaCl2
but v have use the ammonia buffer in titration with EDTA is complex formation.............
first we have add ammonia buffer to hard water MgCl2 is form the complex with NH3Cl as metal complex............After addition of EDTA. EDTA replaces the NH3 After completion of reaction the solution libarates EDT Acetate. This acetate react with E.Block-T give end point..............
| Is This Answer Correct ? | 11 Yes | 15 No |
Answer / rakesh akhaury
Physical Chemistry, Analytical Chemistry ,General Chemistry ,Power Plant boiler water Analysis
| Is This Answer Correct ? | 0 Yes | 4 No |
Why we use caffeine for HPLC calibration in Detector wave ength accuracy test
60 Answers Arvind, Aurobindo, Cipla, Reddy Labs, Shasun Chemicals,
How to prepare ppm solution of Nacl form its salt?
key components in hplc?
what is %labelled amount in content uniformity of dosage unit and its calculation?
what is analytical chemistry all about?
what is the difference between IR and FTIR instrument analysis
If mass balance is not passing in forced degradation in method validation that method is suitable or not?
1 Answers Aurobindo, Dr Reddys, Reddy Labs, Wockhardt,
If we change lenght of ph eletrode wire then it will affect on ph ?
why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?
why 6 tablets use for dissolution
1 Answers Cadila, IPCA, SUN, Teva Pharmaceuticals,
What is difference b/t uv detector and rid
What is difference b/w IR&NIR