Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


i am swathi, b.tech 4th year.
In smps(switched mode power supply)we are using
diodes,mosfets,igbts for controling of current.
And my question is why we did not use thyristors(scr)? it
is also act as a switch,then what is the drawback of scr as
compared to above transisters> if we use the scr,then what
is happening ? plz give reply as soon as possible bcoz i
am doing project on smps. plz frnds i want ans for
that. if anybody know the ans plz send to my e-mail
id /swathi.tadakapally@gmail.com/

Answers were Sorted based on User's Feedback



i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / nithi

SCR cannot be used due to the following reason.

1.we have to design commutation circuit for SCR.(this will
increase the complexity of the circuit)

2.cost of SCR is higher than MOSFET,TRANSISTOR & IGBT.

3.SCR is current controlled device .This will increase the
load on the triggering circuit.

4.The voltage drop & power loss in SCR is somewhat higher
than mosfet,igbt & transistor.

5.moreover,the switching frequency of the SCR is very low
(around 1khz).

so,I think it is better to use MOSFET,IGBT & TRANSISTOR as
a switching device in SMPS.OK............

Is This Answer Correct ?    19 Yes 3 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / prasad,clp(power)

Hi dear this is prasad from clp (power)...we can use
thyristor(scr) but for scr we have to design firing angle
circuit separatly,we have to check whether scr is
triggering or turning on exatctly as per our requirements
or not and for high power applications it is better to
diodes,mosfet,igbts..in these we wont face firing angle
circuit design problems...bocz for the SCR firing circuit
is the heart hope so....

Is This Answer Correct ?    10 Yes 6 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / g venkateswarlu

hi dear swathi,as per your question SCR act as switch but it is current controlled device and its operating frequecy is 400-500hz, voltage drop less than 2 volts,and its application are dc motor control and rectifier and inverter. where as MOSFET AND IGBT voltage control device and above nithi ans also correct

Is This Answer Correct ?    0 Yes 0 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / anjun

hi swathi....its better to ask in GATE FORUM, where u will find correct ans......Anjun

Is This Answer Correct ?    0 Yes 2 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / w

Yes u can use the SCR

Is This Answer Correct ?    1 Yes 8 No

Post New Answer

More Electrical Engineering Interview Questions

What are all present producing cost of Per KWH of various Fuel?

0 Answers   Sanmar,


short circuit test of transformer gives what?

9 Answers   NTPC,


Difference between transmission line and cable?when ever a large water channel has to crossed it is easier to use cable then transmission line why?

1 Answers  


Can anybody explain Why starters are not used for motor starting in industries?

9 Answers  


placement paper samples of mspl company

0 Answers   MSPL,


why in India it is maintained for exactly 50HZ frequency, why it is not that 49Hz,why it is so?

2 Answers  


What is the role of power pack in substation protection system?

0 Answers   Facor,


What is the better way of passing 400 amp from sending end to receiving end ? By overhead line or underground cable and why ? if underground cable then how much depth require ?

1 Answers   Aditya Birla, HCL,


Why Neutral Isolation is required?

0 Answers  


As Electricity Generates in MW I w'd like to know What are the factors we have to consider regarding the transmission of electricity from generation station to Public uses(230 V)

1 Answers  


True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)

0 Answers  


what is the difference between cable routing and scheduling?

4 Answers   Techno Labs,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)