Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why alternators are rated in KVA?

Answers were Sorted based on User's Feedback



Why alternators are rated in KVA?..

Answer / ramprasad thorat

as the copper loss depends on current and core loss depend
on voltage so it is easily possible to find the efficiency
of the alternator. also at the time of manufactoring we dont
know the power factor of the load. so the alternators rating
is in VA.

Is This Answer Correct ?    2 Yes 3 No

Why alternators are rated in KVA?..

Answer / nitin

as the load (i.e. resistive /inductive / capacitive )on the
alternator / transformer is not defind so that the
laternator / transformer rating in kva.

kw= sqrt3*v*i*cosQ

resistive p.f=0,
inductive p.f=lagging
apacitive p.f.=leading

Is This Answer Correct ?    5 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

What is your favorite aspect of the engineering field?

1 Answers  


In a HT switchboard where Nos. of Transformers are connected, how to decide Incoming cable size? Whether Cable should be rated for connected load or maximum demand?

1 Answers   Power Grid,


Describe Non I.S. Earth System and why is it used?

0 Answers   KPJV,


meaning of two lines in between the transformer single line diagram??

3 Answers  


While elctrical load on DG,capacitor banks kept off why so? If capacitor banks on is their any effect DG?

4 Answers   IL&FS Infrastructure Leasing Financial Services,


Name the component u would expect to find in a switchgear assembly?

0 Answers  


What is the difference between rated and maximum speed of 3phase induction motor.....? Can the motor speed exceeds the rated speed..?

1 Answers  


what is the difference b/w absolute encoder and incremental encoder?

0 Answers  


how work a harmonics filter(L-C combition).

1 Answers   Bhel,


sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board"

0 Answers  


Difference between hopkinson and swinburne's test

1 Answers  


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)