HOW TO CALCULATE WAKE FREQUENCY FOR THERMOWELL???WITH OUT
SOFTWARE..
Answer / gk3000
wake frequency
Fw = 2.64 x Fluid velocity(feet/sec) / Dia. of well tip
(inch).
Refer to ASME PTC 19.3
| Is This Answer Correct ? | 14 Yes | 2 No |