Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

VECL,

2511

Can a generator rated 400 V, 60 Hz be used in a 50 Hz System? Yes or No ? Why ?

VECL,

1 2366

What is meant by load angle of an alternator? Upon what factors does the load angle depend?

VECL,

3002

How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?

VECL,

2180

which of the following motors is non-self starting?

SS Solutions,

3 4732

We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected. Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT. My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT. Please guide me.

KPTCL,

2 3751

how a circuit breakers work at fault condition .plz give a specified answer.

Regen Powertech,

1 2863

What is industrial plc

TCS,

1821

i am getting to neutral earth voltage zero ,is this a perfect earthing ?

3 4417

How we can defined theecopper cable size if we know the aluminium cable size?

Cummins,

1874

what is effect of length of air gap on performance of dc motor and generator?

DEI,

1886

How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

AMS, JK Lakshmi Cement,

1769

how to select fuse rating for a 3-phase motor ???

1802

why the power factor of the induction motor is low?

1 2477

why we don't use earthing as neutral?

1 3513


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is the resistance of the field winding of a d.c. Shunt generator kept low?

1112


What are all present producing cost of Per KWH of various Fuel?

2604


HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT SWITCH BOARD,MLDB,ACB,BUSBAR,ETC...?

3947


what do u understand from filter factor of reactor?

1964


what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?

2111


What is the tube exial fan?

2210


how to compute kAIC?  with formulas...

4241


What is the difference between type1 and type2 relay protection co-ordination for motor feeders

2227


How can ou verify the size of conductor 50Sq.mm ACSR

1952


I am a possesor of c licence from 1993. I forgot to renew during the year 1998. During that time I was working at TNEB to till date. Is there any possibility to get renewed? or to apply for a new one?

2040


EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.

2320


How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.

1990


substation+ plc system

2080


What are the factors influence the choice of an electrc drive?

2080


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2346