Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What is the mulplying factor of trivector meter (11kv) having ct ratio 100/5 amp.

2 3031

Which type of transformer used in lighting load?

IMFA,

2 3361

Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

Shree Mayur Engineering,

1554

what is the practical application of full adder circuit?

College School Exams Tests,

1816

How to calulate Locked rotor amper(LRA) for compressor type motors?

MAF Dalkia,

1732

how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)

1609

How does a clampmeter measures dc current

1 2769

Does Rheostat can use for power factor correction?

GOMS,

1 2957

we have provided 30 mA rccb to water cooler.but we feel shock in cooler body.what is the reason?

FCC,

3 4600

What is dry and wet flashover.

1 3640

What is meant by pilot exciter and its working?

2 8473

if vcb make contact but output notreach give the reason?

VVF India,

2 3353

my diploma certificate in my higher education college

Aastha Spintex,

1583

I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1700

I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1644


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Define ohm’s law for a.c (alternating current)?

1015


Explain about p.t?

1048


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1990


What will happend if given Vfd out put to step up transformer

1772


What is the instrument to check the rotating diode fuse of alternator in running conditions?

2438


how to calculate the formula of cable size if motor kw is given

2206


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

2044


How many types of faults are there in 3 phase power system?

1051


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

2225


Can anybody just suggest about the scope of Electrical design with ETAP software?Just guide me?

3760


what are the application of over current relay?

5171


What is 11 N1 and 12 N2 in single phase Transformer ?

1893


What are the section criteria for cables. Now everywhere XLPE power cable is used or PVC is also used?.

1635


Is there any specialised book to refer about fault level calculation both in MV and LV side??

2037


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2096