How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?
1876How can we design a HVAC Plant room which includes AHU,FCU,Chillers,Cooling towers, Pumps etc & how will they work? any Drawing if possible?
TCS,
2398How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?
1849What type of wiring series or parallel is used for conventional and addressable type FAS & why?
1857hello friends this is krunal here.. i have applied for he officer train in hpcl electrical stream.. any one who have applied before for electrical stream please help me out.. post ur reply to my mail id: krunal_airforce@yahoo.com.. any tips, old questions for paper or any help will do.. plz help me.. your faithfully, Krunal Darji
1944Q. calculate the value of the resistor to be connected in series with a 100W; 230V lamp so that the wattage of the lamp is reduced to 35W
8 8899Post New Electrical Engineering Questions
Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station
wht is embedded systems? what is new inthis field?
How to prepare electrical preventive maintenance plan & shedule of machine tools in manufacturing unit.
what are the condition that makes hooter blow?
Safety of on line ups
what is the clear formula to calculate cable size for a load
Why should we hire you over the others waiting to be interview?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
Can you explain about Restricited earth fault protection scheme
how the aircraft outer body and inner body is separated ?
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
Why choke coil is connected in series with starter in tubelight??why starter is connected in parallel to tubelight??
hi frds, i m electrical engineer.can i get cdr for electrical engineer if u have then send me on my mail id its jayesh_ee88@yahoo.com.please help me frds