Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

How to set an overload in a motor?

3 6048

What will happen if the generator turns in a wrong direction?

2 5527

What does a permanent magnet generator do?

1 3628

What is excitation?

2 4701

What is the formulae of Megger value for a A.C.Motor

2830

in three pin plug 6 Amp. 220v AC rating. why earth pin diameter is higher than ohter two pin? what its purpose ?

6 8963

when we connect the capacitor bank in series

2 6737

Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

HAL,

2003

We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.

HAL,

1954

What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2314

How to design grid earthing

1 4561

resistivity of copper

1 3286

In a company the lines carrying 33KV but the load is below 10000Volts so we know that <11KV we can put 11KV lines but the lines are 33KV,..so how we can step down the voltage to 11KV with out erecting a substation

1 2958

What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.

2423

What is the basic principle of circuit breaker?.. I read that it works on electro-mechanical principle... Does it require both electric n magnetic conversion to act?

3 6285


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is physical distance of isolator to VCB in 33/11kv sub stations

2095


why is control bus bi-directional?

2115


At what speed an electric car can run with 2 HP motor of weighing 400 kg?

1782


A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

2373


can some one clearly explain why -48 volt DC use in telecom site????

1645


how does the thyistor work in dc drive?

1943


why tertiary winding is used in transformer with diagram?

2210


what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field

1969


help me with the question that might be ask on the interview for technical position

2258


sir pls send the je exam - 2008 and other model question papers..

2030


TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?

1902


is it value of power factor is more than unit. whats effects in the source supply

2045


Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.

9534


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

2308


WHAT IS THE DIFFERENE IN ACTION OF MCB,MCCB,RCCB

2379