Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1848

WHY WE DO NOT TAKE THE POWER FACTOR MORE NEARER TO UNITY IN AC GENERATOR?

1 4279

in how many ways we can make induction motor to run in reverse direction?

5 7183

how capacitance is neglected in short transmission lines ?

BMC, Qucab,

1 17627

at high temperature conductivity increases for conductor what will happen for long transmission when temperature is high?

1 4208

I have connected 04nos. earthings to a transformer through 04nos. earthing pits seperately. 02nos. earthings are connected to T/F body, and 02nos. earthings are connected to T/F neutral.T/F capacity is 2000KVA, 11KV/415V. But after completing of 02 years successful operation ,we are facing following problems- 1. CT/PT occured blast one time 2. HT cable box occured blast two times 3. One body earthing strip and one neutral earthing strip of transformer are overlapping at some places. Whenever these two strips are pressed at overlapped points, they made spark. What is the reason of spark? Please explain the reason & rectification of above problems

5 10057

when we r using single phase load and we have power cable of 3.5core with .5 of neutral and neutral is suppose to the returen path of the phase how much current will flow in the neutral.reply.

2 4885

why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.

1821

What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?

Jindal,

1990

Can you use step up generator transformer of voltage ratio 16.5kv/420kv in place of step up generator transformer 15.75kv / 420 kv

1 3583

What is the difference between KW & KVA ?

9 15649

What is power factor ?What are the benefits of improved power factor & how. Please explain with examples.?

ABB,

5 12824

Advantage of LT panel vs HT panel

2883

what is self capacitance of inductor

Bhel,

2386

How much no load current of synchronous motor

Nirma, Sulphur Mills,

2062


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

We have two parts in generator, electrical & mechanical. how it works?

1913


I want to know Electrical Circuit?

2128


what is the meaning of 0.5ohm Resistance

1818


In how we connect watt meter for open & short circuit test of a single phase transformer.

6637


How PSV sizing being done

2281


how we find transformer capacity by ohm

2151


Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)

1862


I am a electrical engg. diploma holder,applied for junior engineer (electrical),Kolkata RRB. Have I to attend all electrical,mechanical&civil portion in written exam.???

15589


Transmission through a short line depends on

2212


What is grid collapse? what is the reason for it?

2076


What is the maximum and minimum rating of UPS?

1448


How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current

1507


Why Ac Systems Are Preferred Over Dc Systems?

1263


What are the reasons for the parallel operation of transformers?

1092


What is the actual calculation for transformer short circuit test?.

2431